Inductiekookplaat
Draws 3.7 to 7.4 kW. On a shared circuit you take out the rest of the kitchen as soon as you cook on two zones at once. Often also needs three phases.
Adding a circuit to your consumer unit in Amsterdam — € 265 including the breaker, wiring back to the unit and RCD configuration. Count your free modules below to see whether it fits or whether replacing the unit is the cheaper route.
Count the empty spaces next to the breakers in your meter cupboard — one breaker is one module wide. Then tick what you want to add and we calculate whether it fits and what it costs.
Not sure how much space is free? Send a photo of the open meter cupboard via WhatsApp — we will count it for you.
Adding a circuit is rarely a matter of taste. Usually there is a concrete reason: the appliance draws too much, it must not trip, or it causes faults for everything else.
Draws 3.7 to 7.4 kW. On a shared circuit you take out the rest of the kitchen as soon as you cook on two zones at once. Often also needs three phases.
Both with a heating element of well over two kilowatts. Together on one circuit with the fridge is exactly the combination that fails on Christmas Day.
Motors with leakage current that trip a shared RCD. On a dedicated circuit — preferably with its own RCBO — a broken pump does not shut down your whole home.
The heaviest appliance in the house, and it runs for hours. The requirement is a dedicated circuit with the right type of RCD — this is never a tap off an existing circuit.
These must not trip because a lamp blows elsewhere in the home. A dedicated RCBO makes the circuit independent of the rest.
Not because they draw a lot, but because it is expensive if they trip while you are away. A dedicated RCBO isolates them from every fault elsewhere in the house.
A full consumer unit is not a dead end, but the cheapest fix is not always the wisest. Below is what we weigh up at the survey.
| Optie | Wat het is | When it makes sense | Indicative price |
|---|---|---|---|
| RCBOs | Breaker and RCD in one module instead of two | You want one or two extra circuits and the unit is otherwise fine | € 185 each |
| Groepen samenvoegen | Twee lichte groepen die apart zitten weer bij elkaar | Rarely — only if the load allows it and nothing in the bathroom or kitchen is on it | € 195 |
| Fit a sub-board | Een tweede kastje naast of onder de bestaande | When the meter cupboard is too small for a larger unit and the existing installation is sound | € 495 + groepen |
| Kast vervangen | New, roomier unit with spare capacity | Vanaf drie extra groepen, of als de kast ouder is dan 20 jaar | from € 745 |
One or two extra circuits cost € 265 to € 530 and almost always still fit. From three it becomes a calculation: adding three circuits costs € 795, while a new 9-circuit unit with three RCDs costs € 945 — for a hundred and fifty euros more you then have a unit that lasts another twenty years, with spare capacity and an inspection report. In that case we advise replacement, even though the smaller job is easier for us.
The component itself costs a few tens of euros. What you pay for is that the circuit is correct afterwards: the right cable size for the right breaker rating, the right RCD protection, and a unit that still meets the standard.
A breaker protects the cable, not the appliance. Put a 16 A breaker on a 1.5 mm² wire and that wire can heat up without the breaker ever tripping. The pairing must match: 2.5 mm² at 16 A, 1.5 mm² at 10 A for lighting. So we pull the cable from the unit instead of tapping somewhere.
For a charger or an inverter a standard type A RCD is not always enough — that needs type B or A-EV, depending on the DC component the device produces. That is exactly the detail skipped at a hundred-euro handyman price.
Adding a circuit changes the balance in the unit. If after your new circuit an RCD has five circuits behind it, that no longer meets the rule of four maximum. We then redistribute immediately, without a separate line on the invoice.
Afterwards we test the new circuit — insulation resistance and RCD trip time — and update the meter-cupboard card. That last part sounds like a formality, but it is the difference between “circuit seven” and “circuit seven: dishwasher and oven, kitchen” when something trips in five years.
The first circuit costs €265, each additional one in the same visit €195. Call-out, isolation and testing only need to happen once. If you know something else will be added within a year, have it done in the same visit.
Including materials, labour, testing, labelling and call-out within Amsterdam.
| Add a circuit — first circuit | per circuit | € 265 |
|---|---|---|
| Add a circuit — each further one in the same visit | per circuit | € 195 |
| Fit or replace an MCB | per automaat | € 165 |
| Fit an RCBO (saves 1 module) | each | € 185 |
| Fit a 30 mA RCD | each | € 215 |
| Type B or A-EV RCD for charger or inverter | each | € 285 |
| Groepen herverdelen en opnieuw labelen | per unit | € 195 |
| Fit a sub-board next to the existing unit | per unit | € 495 |
| Meterkastkaart bijwerken | per unit | € 65 |
| Connect washer or dryer on its own circuit | per apparaat | € 195 |
|---|---|---|
| Connect a dishwasher or oven | per apparaat | € 175 |
| Connect induction hob (perilex or 3-phase) | per connection | € 285 |
| Connect air-con or heat pump electrically | per unit | € 385 – 435 |
| Connect a solar inverter | per omvormer | € 420 |
| Install 11 kW EV charger, excl. unit | per installation | € 850 |
| Nieuwe leiding trekken in buis | per metre | € 44 |
| Extend consumer unit to store or garage | per job | € 625 |
| Consumer unit 1-phase — 9 circuits | per unit | € 945 |
|---|---|---|
| Consumer unit 1-phase — 12 circuits | per unit | € 1.145 |
| Consumer unit 3-phase — 12 circuits | per unit | € 1.345 |
| Upgrade 1 → 3 phase, installation work | per home | € 695 |
| NEN 1010 inspection with report | per home | € 295 |
All amounts include materials, labour and 21% VAT, valid in 2026 for Amsterdam and surroundings. Full price list with more than 180 rates →
€ 265 including 21% VAT for the first circuit. That covers the breaker, correctly sized cable from the unit, RCD setup, testing with protocol, updating the meter-cupboard card and call-out within Amsterdam.
Each further circuit in the same visit costs € 195, because call-out, isolation and testing only happen once. The cable and socket to the appliance are extra, depending on distance.
Open the meter cupboard and look at the row of breakers. Each breaker is one module wide; empty slots are usually covered with a blank or a break-out section of the cover strip. Count those slots — that is your free space.
A standard circuit takes one module, an RCBO two, and an extra RCD also two. Use the space check at the top of this page, or simply send us a photo of the open cupboard via WhatsApp; we count it for you and say straight away whether it fits.
Four options. RCBOs combine breaker and RCD in two modules instead of three, often freeing just enough for one or two extra circuits. Merging two light circuits can work sometimes, but is rarely wise. A sub-board next to the existing unit is an option if the cupboard is too small for a larger unit. And fourth: replace the unit.
The tipping point is around three extra circuits. Adding three circuits costs € 795; a new 9-circuit unit € 945. For a hundred and fifty euros more you then get spare capacity, three RCDs and an inspection report. Then we advise replacement, even though the smaller job is easier for us.
For appliances that draw a lot (induction, oven, dishwasher, washer, dryer), for appliances that run for long stretches (charger, heat pump, air-con), and for appliances that must not trip because it is expensive when they do (freezer, boiler system, server rack).
For that last category it is not about power but independence: with its own RCBO, a broken garden light will not shut down your freezer while you are on holiday.
Adding one circuit takes about an hour; two to three circuits one and a half to two hours. During the work the unit is without power — allow half an hour to an hour.
If a cable and socket are also needed, time depends on distance and whether chasing is required. We estimate that at the enquiry; it usually stays within half a day.
Technically it is not complicated, but three things often go wrong. The breaker rating must match the cable size, otherwise the breaker does not protect the wire. For a charger or inverter a standard type A RCD is not always enough. And after the change the split across RCDs must still be correct.
Also: if fire or water damage occurs and the installation was altered by an unrecognised party, that becomes a conversation with your insurer you do not want. For € 265 that is a thin saving.
An MCB protects the cable against overload and short circuit — it trips if too much current flows through it. An RCD protects people: it trips if current leaks away, for example through a body to earth.
An RCBO is both in one component, two modules wide. That saves space in a full unit, and it has a second benefit: that circuit stands entirely on its own, so a fault there does not take out the rest of the home. We use them as standard for chargers, freezers and boiler systems.
Yes. Adding a circuit costs € 265 including 21% VAT for the first one and € 195 for each additional circuit in the same visit — covering the breaker, correctly sized cable back to the consumer unit, RCD configuration, testing with a measurement record and an updated circuit chart.
Not sure whether your consumer unit has space? Send a photo of the open unit via WhatsApp and we will count the free modules for you and tell you straight away whether it fits or whether replacing the unit is the better option.
Send a photo of your open meter cupboard — we count the free slots and say whether adding is possible or whether replacement works out cheaper.
If you choose “as soon as possible”, we call within four hours during office hours. Outside those hours, the next morning.
You speak to someone who does the work and can already say on the phone what is going on and roughly what it costs.
Tell us which language you prefer and we will make sure the right colleague calls.
The home survey is free too, with no call-out fee. You are not committed to anything.
One photo of the open meter cupboard tells us more than ten minutes on the phone. We look at it free of charge and say honestly whether anything needs doing — even if the answer is “no”.
Send photo via WhatsAppA new kitchen, an EV charger or a full consumer unit — those are the three usual triggers in practice.
The hub page with the price calculator, circuit check and the full price list of more than 180 rates.
Read moreWhen replacement is really needed, how many circuits you need and what a new unit costs.
Read morePrice per point, how many a room needs and the volume discount from six points.
Read more1 or 3 phase, load balancing, cable run and charge points in a shared HOA garage.
Read more